Basic Info.
Model NO.
MPO-MPO patch cord
Certification
RoHS, CE, ISO9001, CCC
Brand
Consem
Sheath Material
PC
Cable Type
Singlemode and Multimode
Insertion Loose
0.2dB
Cable Diameter
Mini Round Cable Max4.5mm
Reture Loose
APC60dB PC 50dB
Mating
MPO 500 MTP 1000
Operating Temperature
20ºC~70ºC
Outer Sheath Material
PVC LSZH
Storage Temperature
-40ºC~80ºC
Bending Radius Static/Dynamic
10d/20d
Test Wavelength Nm
Sm:1310/1550 mm:850/1300
Length
Customized
Return Loss Min
Sm APC 60dB mm PC 20dB
End Face Type
PC and APC
Insertion Loss
Standard≤0.35/0.7 Typical/Max
Fiber Type
Sm G652 G655 G657 mm Om1- Om5
Transport Package
Follow Customer
Specification
follow customer
Trademark
Takfly
Origin
China
HS Code
8544700000
Production Capacity
5000PCS /Week
Product Description
factory supply custom made fiber patch cord MPO-MPO series, MPO patch cord
Note: Factory Can custom-made as your datasheet. just send me inquiry details.
MPO WORKSHOP:
Related MPO patch cord series pictures:
MPO/MTP High Density Fiber Patch Cord
1. CABLE Quality Assurance System:
* Test Specifications for Bellcore GR-409-core
* Smoke density Purpose IEC-61034
* Halogen Acid Content IEC-754-1
* Flame Resistance IEC 60332-1, IEC 60332-3
* Conform to WEEE RoHS standard.
2. Fiber Type: OS2/OM3/OM4
Fiber Count: 4/8/12/24 core
Cable Type: Bare fiber/Flat/Round
Item | Parameter | ||||
MPO/MTP Connector | Standard SM | Low Loss(Elite) SM | Standard MM | Low Loss MM | |
Insertion Loss | Typical | 0.35dB | 0.20dB | 0.35dB | 0.20dB |
Maximum | 0.75dB | 0.35dB | 0.60dB | 0.35dB | |
Return Loss | ≥60 for APC (8 Angle Polish) | ≥20 for PC | |||
≥50 for PC | -- | ||||
Male/Female | Male: With Pins, Female: Without Pins | ||||
Tensile Strength | ≤0.3 (Max 66N) | ||||
Vibration | ≤0.3 (10 ~ 55Hz) | ||||
Thermal Cycle | ≤0.3 (-40 ~ 75ºC, 21Cycles) |
Generic Connector Termination:
Fiber Type | Single Mode | Multi-mode | ||
Parameter | UPC | APC | UPC | |
Insertion Loss Maximum (dB) | ≤0.3 | |||
Return Loss (dB) | ≥50 | ≥60 | ≥35 | |
Durability (dB) | ≤0.2 500 matings | |||
Working Temperature(ºC) | -40 ~+85 | |||
Testing Wavelength (nm) | 1310/1550 | 850 |
MPO/MTP Fan-out Patch Cord
Characteristic:
Module optical fiber connections to the torsion of the sequence
Can provide data center and SAN System, simple and flexible
MPO trunk connector fixed on the back of the module
The standard 19" can be installed on any cabinet
Convenient to be installed, moved and added
Main application:
Datacenter rack mount patch panel
The connection between trunk cables to patch cords
Pre-terminated system installation:
In order to ensure the entire connection is in a unified condition, we need to first install the patch panel, cassette module and
Related mounting hardware. Then, say the cables in the designed cable passage position, remove all the protective caps and wraps,
Connect MPO and to all the related MPO sockets, mount and secure the cables with cable ties, simple as that.
Multi Mode | Single Mode | ||
IL | MPO | Single max :0.35db (L) Single Max : 0.60db (G) | Single max :0.35db (L) Single max :0.75db (G) |
LC | MAX :0.10dB(L) MAX :0.15 db (G) | max :0.30db | |
RL | MPO | >20DB | >60DB (8 degree Angle Polish ) |
LC | >30db | >50 db (UPC) >60DB(APC) | |
Mechanical | MPO | <0.2DB, 200 times insertion | |
LC | <0.2db, 500times intertion | ||
Working Temp | -20~ +60 'C | ||
Enviromental | Storage Temp | -40~ + 70'C | |
Install Temp | -5~ + 50'C |